Stainless Steel Vacuum Glove Box with Automatic Regeneration and Pressure Control

Features

Closed Loop Gas Circulation

Inert gas in a closed loop. The gas is circulated by the blower and purifier, H2O, O2 can be removed continuously.

Auto Purging

The replacement of the atmosphere inside the glove box can be achieved automatically by the purging valves.

Automatic Regeneration

H2O and O2 removal material can be regenerated. The regeneration process can be program controlled.

Automatic Pressure Control

The pressure in the glove box is controlled automatically by the Programmable Logic Controller (PLC). Working pressure can be set between +10mba and -10mba. If the pressure goes over+/- 12mbar, the system will be protected automatically.

Eco Mode

The vacuum pump will be activated automatically when necessary, and will turn off after a period of idle time. Blower frequency will be switched to 25Hz when moisture and oxygen level reaches to less than 1 ppm

SPECIFICATIONS:

Model

TMAX-VGB-6

Source voltage

AC110V-240V, Customized

Warranty

Two Years limited warranty with lifetime support

Type

Single section single station

Dimension(L*W*H)

SUS304 stainless steel plate, 1200*800*930mm

Total dimension(L*W*H)

SUS304 stainless steel plate, 1915*830*1830mm

Big transitive cabin

SUS304 stainless steel, DN385*588mm

Small transitive cabin

SUS304 stainless steel, DN150*350mm

Gloves

2 pcs, butyl material, thickness : 0.4mm

Gloves port

DN215mm, Acid and alkali resistant material PPS

Purification system

Single purifying column,  With the remove of water, oxygen function

Control system

6 inch color touch screen, SIEMENS

Vacuum pump

4L/S

Pressure sensor

-2500~2500Pa, Touch screen

H2O concentration

<1 ppm (20 °C, 1 atm) Touch screen

Oxygen concentration

<1 ppm (20 °C, 1 atm) Touch screen

Organic solvent filter

21 L

Working gas

N2,Ar,He

  Specifications of Standard Model of Puification Glove BoX
No. Model No. BoX Dimensions Total Dimensions Operating
Sides
Numbers of Gloves Options
1 GBP800S-2 1200*800*930mm 1915*830*1830mm Single 2 Single or double
purification columns
2 GBP1000S-4 1200*1000*930mm 1915*1060*1830mm Single 4 Single or double
purification columns
3 GBP1000D-4 200*1000*930mm 1915*1060*1830mm Double 4 Single or double
purification columns
4 GBP1200S-2 1200*1200*930mm 915*1260*1830mm Single 2 Single or double
purification columns
5 GBP1200D-4 1200*1200*930mm 915*1260*1830mm Double 4 Single or double
purification columns
6 GBP800S-3 1500*800*930mm 2215*1060*1830mm Single 3 Single or double
purification columns
7 GBP1000S-3 1500*1000*930mm 2215*1060*1830mm Single 3 Single or double
purification columns
8 GBP1000D-6 1500*1000*930mm 2215*1060*1830mm Double 6 Single or double
purification columns
9 GBP1200S-3 1500*1200*930mm 2215*1260*1830mm Single 3 Single or double
purification columns
10 GBP1200D-6 1500*1200*930mm 2215*1260*1830mm Double 6 Single or double
purification columns
11 GBP800S-4 1900*800*930mm 2615*1060*1830mm Single 4 Single or double
purification columns
12 GBP1000S-41 1900*1000*930mm 2615*1060*1830mm Single 4 Single or double
purification columns
13 GBP1000D-8 1900*1000*930mm 2615*1060*1830mm Double 8 Single or double
purification columns
14 GBP1200S- 41900*1200*930 mm2615*1260*1830mm Single 4 Single or double
purification columns
15 GBP1200D-8 1900*1200*930mm 2615*1260*1830mm Double 8 Single or double
purification columns

Notes:
Cabinet water and oxygen content under the standard condition:
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gases
a) Working Gas: N2、Ar、He and etc.
b) Controlling Gas: Compressed air or Inert Gas.
C) Restoring Gas: Mixed gas of working gas and hydrogen.
Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
Remarks: All Single side boxes of 4 gloves are assembled glove box. Numbers of assembled box can be ordered as per customer’s needs. Quantity of purification columns is also designed to be matched according to customer’s requirements

glove box

battery equipment