Product Description

Laboratory Microbiological CO2 Incubators

The
table type anaerobic incubator is composed of constant temperature
incubator, anaerobic operation room, sampling room, gas path and circuit
control system, cabinet frame, etc. The machine is characterized by
good anaerobic environment, good sealing performance, high temperature
control accuracy, good stability, convenient use, good economy and
reliability.

Features

1.Water
jacket and air jacket structure are available, polished stainless-steel
chamber with air duct. Equipped with fan for forced convection,
ensuring good temperature uniformity and the balance of CO2
concentration inside.

2.When door opened, the fan is automatically turned off and stop heating to reduce the pollution caused by the entry of air.

3.Large
LCD screen and PID controller design. PID microprocessor is used to
control temperature and air,meanwhile,the temperature of
box ,water and door are separately controlled by three probes to ensure
high accuracy. ( Air jacket is equipped with two probes to control door
temperature and main body temperature.)

4.Flexible switch, each working status has LCD indication.

5.Alarm function for over-heating, lack of water, unaspirated, ensuring the safe operation of the equipment.

6.Equipped with sterile air filtration devices and UV light system to reduce pollution.

7.Natural
evaporation for humidification, so that the chamber can maintain good
humidity and the humidity can be displayed on screen.

8.Adopt
gilded infrared probe in the detection of CO2 for precise measurement.
The sensor life expectancy is up to 15 years. With alarm function for
over concentration, slow concentration rising and  unaspirated. The
CO2 concentration in the working room can be set arbitrarily within the
range of 0-20%, and its control adopts microcomputer data analysis and
intelligent P.I.D control. And it has super concentration. Alarm for too
slow concentration rise and gas cut-off.

9.Equipped with leakage protection.

10.It is equipped with auxiliary temperature controller to ensure that the machine can work normally when the main temperature control is out of control.

11.90 ℃ high temperature disinfection.

SPECIFICATIONS

Model

TMAX-LCI-85

TMAX-LCI-165

TMAX-LCI-270

Chamber Volume

85L

165L

270L

Temperature Range

RT+3~60℃

Display Resolution

0.1℃

Temperature Stability

≤±0.2℃

Temperature Uniformity

≤±0.3℃

CO2 Range

0~20%

CO2 Control Resolution

±0.1%(imported sensor)

Humidity Method

Natural Vaporization

Power Supply

AC220V,50HZ

Power Rating

600W

900W

1400W

Chamber Size (W×D×H)cm

40×42.5×50

50×51×65

60×60×77

Exterior Size (W×D×H)cm

55×57×82

65×73×105

72×75×112

Shelves(standard/maximum)

2/10

2/13

3/16

Optional parts

1. Automatic humidification system

2. 140 ℃ high temperature sterilization

CO2 Incubator