3/4 Analysis Stations 4 Degas Stations Aperture Analyzer and Surface Area Analyzer
- Model Number:
- TMAX-3H-2000BET-A
- Compliance:
- CE certificate
- Warranty:
- Two Year Limited Warranty With Lifetime Support
- Payment:
- T/T, Credit Card, Paypal, LC, Western Union
- Delivery Time:
- 3 Days
- WhatsApp:
- +8618659217588
- WeChat:
- 18659217588
Product Description
3/4 Analysis Stations 4 Degas Stations Aperture Analyzer and Surface Area Analyzer
3H-2000BET-A provides standard sample reference method, single-point and multipoint BET surface area measurements with speed, accuracy, and reliability. Samples having surface areas from 0.01 m2/g to over 1,000 m2/g are easily accommodated.

The 3H-2000A/BET-A -High Efficiency Surface Area Analyzer
3H-2000BET-A measures surface area using the flowing gas method, which involves the continuous flow of an adsorptive and inert gas mixture over the sample at atmospheric pressure.
The 3H-2000BET-A’s reproducibility is better than 1.5%. The 3H-2000BET-A features a built-in Dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of the sample analysis.
Single injection calibration provides fast start-up and high sample throughput. Specially designed sample holders can be attached and removed from the instrument with one hand. These quick connect/disconnects have a built-in isolation valve to prevent sample contamination.
The 3H-2000BET-A features a Dewar support latch system that provides one-handed convenience and safe-guards against LN2 spills. Simple in design, the 3H-2000BET-A requires minimal training time and leaves little chance of operator error. Automatic mode switching for adsorption and desorption is accomplished without operator attention. The low purchase price of the 3H-2000BET-A and its accessories make this instrument one of the most inexpensive ways for a laboratory to begin measuring BET surface area.
Features
1. Ultra-stable detector eliminates drift and need for constant readjustment.
2. Cold trap conveniently Recessed at the side of the instrument. This placement reduces the chance of breakage .
3. Single-injection calibration requires only one control setting. Adaptable to any non corrosive adsorbate mix.
4. All controls and displays are at eye/arm level, out of spill zone.
5. Built-in sample preparation.
6. The 3H-2000BET-A features a built-in dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of sample analysis
7. The thermal conductivity detector eliminates temperature-induced drift resulting in highly repeatable results.
8. Single-injection calibration provides fast start-up and high sample throughput.
9. The 3H-2000BET-A features a dewar support latch system that provides one-hand convenience and safeguards against liquid nitrogen spills.
Selection Guide
|
3H-2000A |
3H-2000BET-A |
|
|
Degas Stations |
4 |
4 |
|
Degas Method |
Flow Gas |
Flow Gas |
|
Analysis Stations |
3 |
3/4 |
|
Standard Sample Reference Method |
√ (3 test results in 30min) |
√ (3 test results in 30min) |
|
BET |
--- |
√ (4 test results in 150min) |
|
Gas |
Mixed gas(20% Nitrogen,80%Helium) |
Two bottle of pure gas(Nitrogen and Helium) |
|
Total volume |
--- |
--- |
|
Pore Size |
--- |
--- |
|
Vacuum Pump |
--- |
--- |
|
Cold Trap |
√ |
√ |
Test Reports














