5V100mA Four-Range Battery Testing System Adjustable Cell Holders & Software
- Compliance:
- CE certificate
- Warranty:
- Two Year Limited Warranty With Lifetime Support
- Payment:
- T/T, Credit Card, Paypal, LC, Western Union
- Delivery Time:
- 3 Days
- WhatsApp:
- +8618659217588
- WeChat:
- 18659217588
Product Description
5V100mA Four-Range Battery Testing System Adjustable Cell Holders & Software
SPECIFICATION
|
BTS-5V100mA Four-Range Battery Testing System |
|||
|
Equipment material code |
CT-4008Q-5V100mA |
||
|
Indicator project |
Indicator parameters |
||
|
Enter the power supply |
AC 220V ±10% / 50Hz |
||
|
Input active power |
40W |
||
|
Resolution ratio |
AD :24bit;DA:16bit |
||
|
Input impedence |
≥1GΩ |
||
|
Voltage |
Constant voltage range control |
10mV ~5V |
|
|
Minimum discharge voltage |
-5V |
||
|
Accuracy |
± 0.01% of FS |
||
|
Stability |
0.02% of FS |
||
|
Current |
Output range per channel |
Range 1: 0.2 μA~0.1 mA; Range 2: 0.1 mA ~1 mA; Range 3: 1 mA ~ 10 mA; Range 4: 10 mA ~ 100 mA |
|
|
Accuracy |
± 0.01% of FS |
||
|
Constant pressure cut-off current |
Range 1:0.1μA; Range 2:1μA; Range 3:10μA;Range 4:0.1mA |
||
|
Stability |
0.02% of FS |
||
|
Power |
Single-channel maximum output power |
0.5 W |
|
|
Stability |
0.04% of FS |
||
|
Time |
Current response time (10% FS to 90% FS) |
≤1ms |
|
|
Working step time range |
(365 * 24) hours / work step |
Supported in time format: 00:00:00:00 (h, min, s, ms) |
|
|
Data logging |
Data recording conditions |
Minimum time interval: 100ms |
|
|
Record frequency |
10Hz |
||
|
Charge |
Charging mode |
Constant current charging, constant voltage charging, constant current constant pressure charging, constant power charging |
|
|
Cut-off condition |
Voltage, current, relative time, capacity, - △ V |
||
|
Discharge |
Discharge mode |
Constant current discharge, constant voltage discharge, constant current constant voltage discharge, constant power discharge, constant resistance discharge |
|
|
Cut-off condition |
Voltage, current, relative time, and capacity |
||
|
Pulse mode |
Charge |
Constant current mode, constant power mode |
|
|
Discharge |
Constant current mode, constant power mode |
||
|
Minimum pulse width |
500ms |
||
|
Pulse number |
A single pulse working step supports 32 different pulses |
||
|
Continuous charge / discharge charge switching |
A pulse step can realize continuous charging switching or discharge switching; (charge-to-charge switching is not supported) |
||
|
cut-off condition |
Voltage, and relative time |
||
|
DCIR test |
Support for custom taking points for the calculation of DCIR |
||
|
Recurrence |
Circulating test range |
1 to 65,535 times |
|
|
Single cycle step number |
254 |
||
|
Loop nesting |
With a nesting cycle function, up to a 10-layer nesting support |
||
|
Protect |
● Power-loss data protection |
||
|
● It has the offline test function |
|||
|
● Safety protection conditions can be set, setting parameters include: voltage limit, voltage limit, current limit, current limit, capacity limit, delay time |
|||
|
IP levels of protection |
Protection level is IP20 |
||
|
Channel characteristics |
The constant current source and the constant voltage source adopt a double closed-loop structure |
||
|
Channel control mode |
Independent control |
||
|
Voltage and current detection and sampling |
Four-line connection |
||
|
Noise |
<45dB |
||
|
Data base |
The MySQL database was used to centralize the test data |
||
|
Upper-computer communication mode |
Based on the TCP / IP protocol |
||
|
Server operating system |
Windows 7 / Windows 10 and above systems |
||
|
Data output mode |
EXCEL2003,2010、TXT |
||
|
Server disk configuration |
500GB |
||
|
CI |
Internet access |
||
|
Leakage current |
0.005μA |
||
|
Number of machine channels |
8 |
||
|
Equipment working environment requirements |
|||
|
Indicator project |
Indicator parameters |
||
|
Operating temperature range |
0℃~40℃; Ensure the measurement accuracy within the calibration temperature (usually 25℃) plus or minus 5℃; Accuracy drift is 0.001% of FS /℃ |
||
|
Storage temperature range |
-10℃~50℃ |
||
|
Relative humidity range of the working environment |
70% RH (no moisture condensation) |
||
|
Storage environment relative humidity range |
80% RH (no moisture condensation) |
||