| 1. Material code |
CE-6016n-100V30A-H |
| 2、Channels information |
| 1. Channels quantity |
Channels quantity in one unit |
16 |
| 2. Main channel |
Channel feature |
Constant current source and constant voltage source dual closed loop control |
| Channel control mode |
Independent control |
| Channel parallel connection |
Support max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode. |
| 3、Power grid side parameters |
| 1.Input power |
AC380V±15% 50/60±5Hz |
| 2.Power factor |
≥99%(Full load) |
| 3.THDi |
≤5%(Full load) |
| 4.Input resistance |
≥1MΩ |
| 5.Input power |
56.5KW |
| 6.Input current |
85.8A/single |
| 7.Overall system efficiency(Max) |
90% |
| 8.Noise |
≤65dB |
| 9.Voltage and current sampling |
Four-wire connection(same port for charging and discharging) |
| 10.Power control module type |
MOSFET |
| 11.Input power wiring method |
Three-phase-five wire system |
| 12.Power input protection |
Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti phase absence, etc. |
| 4、Functions and performances |
| 1. Voltage |
Output range |
Charge:0V~100V |
| Discharge:3V~100V |
| Min discharge voltage |
3V |
| Accuracy |
±0.02% of FS |
| Resolution |
24bit |
| 2. Current |
Output range |
0.15A~30A |
| Accuracy(independent range) |
±0.05% of FS |
| CV cut-off current |
30mA |
| Resolution |
24bit |
| 3. Power |
Single channel output power |
3KW |
| Whole machine output power |
48KW |
| 4. Time |
Current response time |
≤3ms |
| Current conversion time |
≤6ms |
| Min. step time |
0.1s |
| 5. Charge/Discharge modes |
Charge/Discharge modes |
CCC, CVC, CC-CVC, CPC |
| CCD, CVD, CPD, CRD |
| Cut-off condition |
Voltage, Current, ΔTime, Capacity, -ΔV |
| 6. Simulation |
Charge |
Current, Power |
| Discharge |
Current, Power |
| Switch |
Support continuous switching between charge and discharge |
| Cut-off condition |
Time, step line |
| Steps file lines |
1,000,000 |
| 7. Pulse Mode |
Charge |
Current ,power |
| Discharge |
Current, Power |
| Min pulse |
100ms |
| Pulse counts |
Up to 32 |
| Charge and discharge switch |
supported |
| Cut-off condition |
Voltage, ΔTime |
| 8. DCIR |
|
DCIR by calculation |
| 9. Safely protection |
Software protection |
Power off data protection |
| Offline mode function |
| Safety protection conditions can be set, including:voltage lower limit ,voltage upper limit ,current lower limit ,current upper limit ,delay time, etc. |
| Hardware protection |