5V50mA High Current 8 Channels Battery Analyzer Adjustable Cell Holders & Software
- Model Number:
- TMAX-5V50mA
- Input Power:
- 80W
- Dimension(L*W*H):
- 500*550*400(mm)
- Net Weight:
- 15KG
- Compliance:
- CE certificate
- Warranty:
- Two Year Limited Warranty With Lifetime Support
- Payment:
- T/T, Credit Card, Paypal, LC, Western Union
- Delivery Time:
- 3 Days
- WhatsApp:
- +8618659217588
- WeChat:
- 18659217588
Product Description
5V50mA High Current 8 Channels Battery Analyzer Adjustable Cell Holders & Software
SPECIFICATIONS:
5V50mA Battery Tester is
an eight-channel battery analyzer to analyze, voltage 0-5v. Each channel of the
analyzer has independent constant-current and constant-voltage source, which
can be programmed and controlled by computer software.
|
Model |
TMAX-5V50mA |
|
|
Input Power |
AC 220V ±10% / 50Hz |
|
|
resolution |
AD:16bit;DA:16bit |
|
|
Input Resistance |
≥1MΩ |
|
|
Input Power8 |
80W |
|
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
|
Channel Control Mode |
Independent Control |
|
|
Voltage |
Per Channel Voltage Range |
0-5V |
|
Min discharge Voltage |
0V |
|
|
Accuracy |
± 0.05% of FS |
|
|
Stability |
± 0.05% of FS |
|
|
Current |
Per Channel Current Range |
0.004A-0.05A |
|
Accuracy |
± 0.05% of FS |
|
|
Stability |
± 0.05% of FS |
|
|
Power |
Per Channel Output Power |
2W |
|
Stability |
± 0.1% of FS |
|
|
Time |
Current Response Time |
20ms (0-Full Range) |
|
Step Time Range |
≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms) |
|
|
Data Recording |
Record Condition |
Minimum Time Interval: 100ms |
|
Minimum Voltage Interval: 10mV |
||
|
Minimum Current Interval : 2mA |
||
|
Record Frequency |
10Hz |
|
|
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,CPC |
|
End Conditon |
Voltage,Current,Relative Time,Capacity,-ΔV |
|
|
Discharge |
Discharge Mode |
CCD,CPD,CRD |
|
End Condition |
Voltage,Current,Relative Time,Capacity,-ΔV |
|
|
Pulse |
charge |
CCC |
|
Discharge |
CCD |
|
|
Min Pulse Width |
500ms |
|
|
Automated Switch |
Automated switch from charge to discharge for each pulse |
|
|
End Condition |
Voltage, Test Time |
|
|
DCIR |
Support DCIR testing |
|
|
Cycle |
Loop Measure Range |
1~65535 times |
|
Max Steps Per Loop |
254 |
|
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
|
Protection |
Software Protection |
l Power-down Data Protection |
|
l Off-line Testing Function |
||
|
l Setting Protection Condition,Setting Parameter: Low Voltage limit,Upper Voltage limit,Low Current limit, Upper Current limit,Delay Time |
||
|
Hardware Protection |
Additional Anti-reverse Protection Model |
|
|
Voltage and Current Testing Sample |
4-wire connecting |
|
|
Noise |
<85dB |
|
|
Database |
MySQL Database |
|
|
A Means of Communication of Upper Machine |
TCP/IP Protocol |
|
|
Data Output |
EXCEL,TXT |
|
|
Communication Interface |
Ethernet Port |
|
|
Per Unit Main Channels No. |
8 |
|
|
Dimensions (L*W*H) |
3U,about 500*550*400(mm) |
|