5V 60A 8 Channel Battery Tester For Prismatic Cell Testing Machine
- Model Number:
- TMAX-CT-4008-5V60A
- Compliance:
- CE certificate
- Warranty:
- Two Year Limited Warranty With Lifetime Support
- Payment:
- T/T, Credit Card, Paypal, LC, Western Union
- Delivery Time:
- 3 Days
- WhatsApp:
- +8618659217588
- WeChat:
- 18659217588
Product Description
5V 60A 8 Channel Battery Tester For Prismatic Cell Testing Machine
Technical parameters
|
AC Input |
AC 220V ±10% / 50Hz |
|
Input Active Power |
4253W |
|
Resolution |
AD:16bit;DA:16bit |
|
Input Impedance |
≥1MΩ |
|
Voltage |
Constant Voltage Range Control: 0.025V~5V; Minimum Discharge Voltage: 2.5V; Accuracy: ± 0.1% of FS; Stability: ± 0.1% of FS; |
|
Current |
Output Range per Channel: 0.3A~60A; Accuracy: ± 0.1% of FS; Constant Voltage Cut-off Current: 0.12A; Stability: ± 0.1% of FS; |
|
Power |
Single Channel Maximum Output Power: 300W; Stability: ± 0.2% of FS; |
|
Time |
Current Response Time (10%FS~90%FS) Maximum current rise time: 20ms; Step Time Range ① ≤(365*24) h/step; ②Time Format Support 00:00:00:00(h, min, s, ms) |
|
Data Acquisition |
Data Acquisition Conditions Minimum Time Interval: 100ms; Minimum Voltage Interval: 10mV; Minimum Current Interval: 120mA; Data Acquisition Frequency 10Hz; |
|
Charge |
Charging Mode: Constant Current Charging, Constant Voltage Charging, Constant Current/ Constant Voltage Charging, Constant Power Charging; Cut-off Conditions: Voltage, Current, Relative Time, Capacity, -△V; |
|
Discharge |
Discharge Mode: Constant Current Discharge, Constant Voltage Discharge, Constant Power Discharge and Constant Resistance Discharge; Cut-off Conditions: Voltage, Current, Relative Time, Capacity; |
|
Pulse Mode |
Charging: Constant Current Mode and Constant Power Mode; Discharge: Constant Current Mode and Constant Power Mode; Minimum Pulse Width: 500ms; Number of Pulses: A Single Pulse Step Supports 32 Different Pulses; Continuous Switching of Charge and Discharge: One Pulse Step can Realize Continuous Switching from Charge to Discharge; Cut off Conditions: Voltage, Relative Time; |
|
Cycle Life |
Cycle Test Range: 1~65535 times; Number of Single Cycle Steps: 254; Loop Nesting: It has the Function of Nested Loop and Supports Up to 3 Levels of Nesting; |
|
DCIR Test |
Support DCIR calculating with user defined point. |
|
Protect |
Power down data protection; Function of prevention of feedback; The safety protection conditions can be set, and the setting specs include: voltage upper limit, voltage lower limit, current upper limit, current lower limit and delay time; Function of offline test. |
|
IP Protection Degree |
Protection Degree: IP20 |
|
Channel Characteristics |
Constant current and constant voltage adopt double closed loop structure. |
|
Channel Control Mode |
Independent Control |
|
Voltage and Current Sampling |
Four Wire Connection |
|
Noise |
<85dB |
|
Database |
Adopting MySQL database to centralized manage testing data. |
|
Server Disk Configuration |
500GB |
|
Communication Mode of Upper Computer |
Based on TCP/ IP Protocol |
|
Leakage Current |
0.005mA |
|
Server Operating System |
Windows 7 |
|
Data Output Mode |
EXCEL 2003, 2010; TXT. |
|
Communication Interface |
Network Interface |
|
Total Number of Channels |
8 |
|
Working Temperature Range |
0℃~40℃(Within the range of 25±10℃, accuracy drift is 0.005% of FS /℃) |
|
Storage Temperature Range |
-10℃~50℃ |
|
Relative Humidity Range of Working Environment |
≤70% RH(There is no condensation of moisture.) |
|
Relative Humidity Range of Storage Environment |
≤80% RH(There is no condensat |